Satron VCK Consistency Meter

The SATRON VCK is a multichannel optical transmitter, suitable for the measurement of Kappa and Consistency in the pulp mill

Technical Specifications:
Measuring range and span
Zero and Span adjustment
Zero elevation: Calibrated span is freely selectable on the specified range depending from the desired option. This can be made by using keyboard (display option) or HART®275/375 communicator.
Damping
Time constant is continuously adjustable 0.01 to 60 s.
Repeatability
Application Specific
Temperature limits
Ambient: -30 to +80 °C
Process: -30 to + 140 °C
Shipping and storage: -40 to +80 °C.
Output
2 current outputs for Cs: 3-wire (3W), 4-20 mA
Supply voltage and permissible load
24 VDC, -10 %, + 15 %, 100 mA
- 115/230 VAC, -15% ... +10% (device enclosure)
Humidity limits
0-100 % RH
EMC directive 2004/108/EC
EN 61326-1:2005
Construction Materials:
Sensing element 1): AISI316L (EN 1.4404), Duplex (EN. 1.4462), Hast. C276 (EN 2.4819), or Titanium Gr2. Safir glass Coupling 1): AISI316L (EN 1.4404), Duplex (EN 1.4462), Hast.C276 (EN 2.4819) or Titanium Gr2
Pressure class:
PN25
Housing with display, codes N0S & N0T:
Housing: AISI303/316, Seals: Nitrile- rubber and Viton®,
Nameplates: Polyester
dd>
Housing with M12 connector, code H0T:
Housing: AISI303/316, Seals: Viton® and NBR.
Connection hose between sensing element and housing
Codes L and R:
PUR signal cable or hose protected with PTFE/AISI316 braiding
Device enclosure, code K: EN 1.4301 (AISI304)
More Info
Sharp Industries, LLC, Cleaning Systems Press, Chemical, Shreveport, LA